TLZ10 FS (12V)
Single Set-Point Digital Temperature Controller
The TLZ10 Series of controllers has been discontinued and replaced by the Z31-A Series.
TLZ10 to TAC60 Wiring Instructions
TLZ10 to TCP50 Wiring Instructions
TLZ10 Temperature Controller
THE TLZ10 SERIES HAS BEEN DISCONTINUED. THE REPLACEMENT IS THE Z31-A"
* The Tecnologic TLZ10 Series replaces the Tecnologic TDH01 Series
TLZ10 is a digital microprocessor based temperature controller for Cooling or Heating applications and ON/OFF control mode. The instrument has one relay output (SPDT) and one input for PTC or NTC temperature probes, that can be configured. The instrument is equipped with 4 programming keys, a 4-digit display and 1 LED signal.
Other important characteristics of the instrument are: Programmed parameters may be protected by using a personalized password, switching on and off (stand-by) of the instrument using the “U” front key, configuration of parameters via the optional A01 device.
We Include an NTC Sensor.
Other available Inputs: 24 VAC/VDC (L type) and 100...240 VAC (H type).
Features
TLZ10 is a compact, microprossor driven temperature controller great for simple applications where maintaining a single temperature is desired. The TLZ10 is easily programmable for either direct action (cooling) OR reverse action (heating).
TLZ10-FS Specifications
Power Supply: 12 VAC/VDC ± 10% F: 50/60 Hz
Power Consumption: 3 VA
Input(s): Includes an NTC 103AT-2 (10 kΩ at 25 °C) sensor. Will work with a PTC KTY 81-121 (990 Ω at 25 °C) sensor
Measurement range: NTC: -50...109 °C / -58...228 °F; PTC: -50...150 °C / -58 ... 302 °F
Output(s): One (1) 16 amp relay output SPDT 16A-AC1
Case: Self-extinguishing plastic, UL 94 VO
Dimensions: 1/16th DIN, Front Panel 35x75 mm, Depth 64 mm
Mounting: Flush in panel in 29x71 mm hole
Connections: 2.5 mm screw terminal block
Degree of protection of from panel: IP 65, mounted on the panel with seal
Control: ON/OFF
Display resolution: According to the probe used. 1/0. 1/5/0.5
Overall Accuracy: ± 0.5% fs
Sampling rate: 1 sample per second
Compliance: EEC directive EMC 89/336 (EN 50081-1, EN 50082-1), EEC directive LV 73/23 and 93/68 (EN 60730-1)
UL File no. E212227